PY131 Temperature Gauge

  • Measuring ranges : -1 …2500 bar
  • Accuracy: up to 0.1% F.S
  • Wide range of applicable medium temperature
  • Direct contact measurement of high temperature media, improve the pressure response frequency
  • Provide low pressure, medium pressure, high pressure range of rich pressure range

PY 108 High-temperature pressure transmitters use high-temperature resistant pressure sensors as the signal measuring element. The pressure of the measured medium is transmitted to the transmitter through the heat dissipation structure on the transmitter, and the high-precision signal processing circuit is located in the stainless steel housing.
The pressure of the measured medium is transferred to the sensor through the heat dissipation structure of the transmitter. The high-precision signal processing circuit is located in the stainless steel housing, which converts the sensor output signal into standard output signal.

Applications:

■ Filling and packing machinery
■ Dosing technology
■ Level measurement
■ General industrial applications
■ Food and beverage industry
■ Environmental protection, chemical, coating

Product Features:
■ Measuring ranges : -1 …2500 bar
■ Accuracy: up to 0.1% F.S
■ Wide range of applicable medium temperature
■ Direct contact measurement of high temperature media, improve the pressure response frequency
■ Provide low pressure, medium pressure, high pressure range of rich pressure range

■ Pressure ranges: -0.1 ...2,500 bar

■ Accuracy Standard: ≤±0.5 % of span
                         Option: ≤±0.1 % or ≤±0.25%of span¹
                         1) Only for measuring ranges ≥ 0.25 bar

■ Non-linearity (per IEC 61298-2): ≤±0.2%of span BFSL

■ Non-repeatability: ≤±0.1%of span

■ Temperature error in rated temperature range: Rated temperature range: 0 ... 80 °C

■ Mean temperature coefcient of zero point:
        Measuring range > 0.25 bar:≤ ±0.2 % of span/10 KMeasuring range ≤ 0.25 bar: < ±0.4 % of span/10 K

■ Mean temperature coefcient of span: ≤±0.2 % of span/10 K

■ Adjustability of zero point and span: Adjustment is made using potentiometers inside the instrument.
         Zero point: ± 5 % Span: ± 5 %

■ Response Time: 2ms

■ Analog output: 4〜20mA DC (Load resistance ≤750Ω ) , 0〜10 mA DC (Load resistance ≤1.5KΩ ), 1〜5V DC (Load resistance ≥250K ) , 0〜5V DC (Load resistance ≥250K )

■ Load in Ω Depending on the signal type the following loads apply:
                  Current (2-wire):≤ (power supply - 10 V) / 0.02 A
                  Current (3-wire):≤ (power supply - 3 V) / 0.02 A
                  Voltage (3-wire): > max. output signal / 1 mA

■ Power supply The power supply depends on the selected output signal:
                   4 ... 20 mA (2-wire): DC 10 ...30 V
                   0 ... 20 mA (3-wire): DC 10 ...30 VDC
                   1 ... 5 V(2-wire): DC 10 ...30 V
                   0 ... 10 V: DC 14 ... 30 VDC
                   0 ... 5 V: DC 10 ...30 V

■ Overpressure: 5bar or 3×FS, whichever is smaller

■ Electrical connection: Hirschmann connector, waterproof connector optional

■ Thread: 1/4NPT, 1/2NPT, G1/2, G1/4,Others can be customized

■ Material: 316L

■ Ambient conditions: -20...70°C with air humidity ≤95%r.h.

■ Weight: 330 g

Product Information

To learn more about the technical details for options available, review our product information  pages.

Unit Converter

Need to convert measurement units? Check out our quick and easy tool to convert pressure, temperature and flow units of measure.

Unit Converter

Need to convert measurement units? Check out our quick and easy tool to convert pressure, temperature and flow units of measure.

Resources & Tools

Related products

Scroll to Top

Request A Quote