CFMG701 SERIES

CFMG701 Multi-parameter Transmitter

CFMG701 Multi-Parameter Flow Transmitter combines differential pressure sensing, pressure measurement, temperature monitoring and intelligent flow computation in one compact device. Designed for industrial liquid and gas applications, it provides accurate compensated flow measurement while reducing installation cost and simplifying process automation.
Output 0–20 mA / 0–5 V / More Options

Technical Specifications

MEASUREMENT PERFORMANCE

Pressure Range
-1~100bar
Accuracy
0.5% FS

ELECTRICAL & COMMUNICATION

Output
4–20 mA / 0–5 V / 0–20 mA / 1–5 V
Power Supply
12~36 VDC

Product Overview

CFMG701 Multi-Parameter Transmitter integrates differential pressure flow measurement, pressure sensing, temperature monitoring and intelligent compensation algorithms into one compact instrument. It accurately measures liquid and gas flow while simultaneously calculating compensated flow, pressure and temperature values.

Unlike conventional differential pressure flow meters, the CFMG701 combines multiple measurement functions within a single transmitter, reducing installation cost, simplifying system integration and improving long-term measurement stability.

Designed for industrial process automation, it is suitable for water treatment, chemical processing, energy systems, gas distribution and environmental monitoring applications.

Key Features

  • Differential Pressure Flow Measurement
  • Flow, Pressure & Temperature Measurement
  • Automatic Temperature & Pressure Compensation
  • Integrated Flow Totalization
  • Suitable for Gas and Liquid Media
  • Wide Pipe Size Coverage (DN80–DN500)
  • Industrial RS485 Communication
  • IP67 Protection
  • Integrated Flange Installation
  • Low Installation & Maintenance Cost

Applications

Industry Typical Applications
Water Treatment Pure Water, Municipal Water, Wastewater
Chemical Processing Chemical Plants & Process Control
Oil & Gas Natural Gas, Compressed Air, Fuel Gas
Energy Steam & Utility Systems
Environmental Environmental Monitoring
Manufacturing Industrial Automation
Food & Beverage Utility Flow Monitoring
Municipal Engineering Water Supply & Distribution

Technical Highlights

Flow Performance

Parameter Specification
Measurement Principle Differential Pressure
Medium Gas / Liquid
Pipe Size DN80–DN500 (Custom Available)
System Accuracy ±0.5% (Liquid), ±1.0% (Gas)
Range Ratio Up to 20:1
Measurement Functions Flow, Pressure, Temperature
Compensation Automatic Pressure & Temperature Compensation
Flow Calculation Integrated Flow Computer
Totalization Instantaneous & Total Flow

Pressure & Temperature Measurement

Parameter Specification
Pressure Range 0.1–10 MPa (Optional)
Pressure Accuracy ±0.5%
Pressure Resolution 0.01 MPa
Temperature Range −10°C to 80°C
Recommended Operating Temperature 0–60°C
Temperature Accuracy ±1°C
Temperature Resolution 0.1°C

Mechanical Specifications

Parameter Specification
Installation Integrated Flange
Enclosure Industrial Aluminum Housing
Wetted Material Stainless Steel
Process Connection Flanged Installation